Assessment of the density and type of the bio-aerosols associated with nosocomial infection in different wards of the selective AJA hospitals in Tehran
A Rafiee , Vida Pesarakloo , Mohammad Hoseini , Hosein Shabani , A Shahedi
Abstract:   (525 Views)

Background: Evaluation of the type and concentration of microorganisms in the air of a hospital can be an indicator of whether such environments are clean or not, and also to be considered as a source of nosocomial infections. The aim of this study was to identify the type and concentration of Bio-aerosols associated with nosocomial infections in different wards of selected AJA hospitals in Tehran.
Materials and methods: In a cross-sectional and descriptive- analytical study 120 bacterial and 120 fungal samples were collected from the operation rooms, Intensive Care Units (ICUs) and Infectious diseases wards of two studied hospitals (A and B). A passive indoor environment sampling was carried out within 120 days, once every six days.
Results: The average concentration of bacteria in the air of A and B hospitals were 84 and 212 CFU/m3, respectively. Also, the Average concentration of fungal species of A and B hospitals were was 80 and 85 CFU/m3, respectively. The dominant fungal species of these hospitals were Cladosporium (25%) and Aspergillus niger (28%), respectively. Also, Staphylococcus epidermidis was determined as the dominant bacterial species in both hospitals. Significant linear correlation existed between population density and concentration of bio-aerosols.
Conclusion: According to the results of this study, bacterial and fungal bio-aerosol concentrations in the studied hospitals were higher than the existing standards and it indicates the low efficiency of the ventilation system in these hospitals.

 

Keywords: Nosocomial Infection, Bacterial Spores, Fungi, Indoor Air Pollution, Hospital
Full-Text [PDF 759 kb]   (105 Downloads)    
Type of Study: Applicable | Subject: Special
Received: 2017/01/31 | Accepted: 2018/02/17 | Published: 2018/02/17
Add your comments about this article
Your username or Email:

Write the security code in the box >


XML   Persian Abstract   Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Rafiee A, pesarakloo V, Hoseini M, Shabani H, Shahedi A. Assessment of the density and type of the bio-aerosols associated with nosocomial infection in different wards of the selective AJA hospitals in Tehran. EBNESINA- Journal of Medical. 2018; 19 (4) :45-52
URL: http://ebnesina.ajaums.ac.ir/article-1-499-en.html


Volume 19, Issue 4 (Winter 2018) Back to browse issues page
ابن سینا EBNESINA
Persian site map - English site map - Created in 0.06 seconds with 31 queries by YEKTAWEB 3708